0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
G2R-1-SNI DC24(S)

G2R-1-SNI DC24(S)

  • 厂商:

    OMRON(欧姆龙)

  • 封装:

    -

  • 描述:

    G2R-1-SNI DC24(S)

  • 数据手册
  • 价格&库存
G2R-1-SNI DC24(S) 数据手册
General-purpose Relay G2R-@-S (S) CSM_G2R-_-S_(S)_DS_E_1_7 Slim and Space-saving Power Plug-in Relay ■ Reduces wiring work by 60% when combined with the P2RF-@-PU Push-In Plus Socket (according to actual OMRON measurements). ■ Lockable test button models available. ■ Built-in mechanical operation indicator. ■ Provided with nameplate. ■ AC type is equipped with a coil-disconnection self-diagnostic function (LED type). ■ High switching power (1-pole: 10 A). LR For the most recent information on models that have been certified for safety standards, refer to your OMRON website. Model Number Structure Model Number Legend G2R - -S (S) 1 2 3 1. Number of Poles 1: 1 pole 2: 2 poles 4 5 4. Rated Coil Voltage 5. Mechanical operation indicator and Nameplate (S): Models with mechanical operation indicator and Nameplate 2. Terminals S: Plug-in 3. Classification Blank: General-purpose N: LED indicator D: Diode ND: LED indicator and diode NI: LED indicator with test button NDI: LED indicator and diode with test button Note: Contact your OMRON representative for Relays with gold-plated contacts. Ordering Information When your order, specify the rated voltage. List of Models Classification General-purpose LED indicator LED indicator with test button Coil ratings AC 24, 48, 110, 120, 230, 240 DC 6, 12, 24, 48 Diode LED indicator and diode LED indicator and diode with test button DC 6, 12, 24, 48 Contact form SPDT DPDT G2R-1-S (S) G2R-2-S (S) G2R-1-SN (S) G2R-2-SN (S) G2R-1-SNI (S) G2R-2-SNI (S) G2R-1-SD (S) G2R-2-SD (S) G2R-1-SND (S) G2R-2-SND (S) G2R-1-SNDI (S) G2R-2-SNDI (S) Note: 1. The standard models are compliant with UL/CSA and VDE standards. Also, an EC compliance declaration has been made for combinations with the P2RF-@-E, P2RF-@-S and P2RF-@-PU. The Relays bear the CE Marking. 2. Refer to Connecting Sockets, below, for applicable Socket models. 3. When ordering, add the rated coil voltage and "(S)" to the model number. Rated coil voltages are given in the coil ratings table. Example: G2R-1-S 12 VDC (S) Rated coil voltage 1 G2R-@-S (S) Accessories (Order Separately) Connecting Sockets Track/surface-mounting Socket Applicable Relay model Push-In Plus Terminal Blocks No. of poles Back-mounting Socket Screw terminals * PCB terminals Solder terminals Models Models Model Model 1 pole G2R-1-S (S) P2RF-05-PU P2RFZ-05-E P2RF-05 P2RF-05-E 2 poles G2R-2-S (S) P2RF-08-PU P2RFZ-08-E P2RF-08 P2RF-08-E P2R-05P P2R-057P P2R-05A P2R-08P P2R-087P P2R-08A * The structure of P2RF-@-E models provides finger protection. Round terminals cannot be used. Use forked crimp terminals. Accessories for Push-In Plus Terminal Block Sockets (P2RF-@-PU) Short Bars Pitch No. of poles Model * Colors 2 3 7.75 mm PYDN-7.75-030@ Red (R) Blue (S) Yellow (Y) 4 20 15.5 mm Minimum order (quantity) PYDN-7.75-020@ PYDN-7.75-040@ 10 PYDN-7.75-200@ 8 PYDN-15.5-080@ Note: Use the Short Bars for crossover wiring within one Socket or between Sockets. * Replace the box (@) in the model number with the code for the covering color. Labels Model Minimum order (sheet) (quantity per sheet) XW5Z-P4.0LB1 5 1 sheet (60 pieces) Accessories for Screw Terminal Sockets (P2RFZ-@-E) Short Bars Pitch No. of poles 6.8 mm 10 15.7 mm Colors Model Minimum order (set) P2DN-6.8-100S Blue (S) 10 1 One set (order unit) contains 10 short bars and 20 caps. P2DN-15.7-100S Note: 1. Use the Short Bars for crossover wiring within one Socket or between Sockets. 2. Cannot be used on the P2RF-@-E. Labels Model Minimum order (sheet) (quantity per sheet) XW5Z-P2.5LB1 5 1 sheet (72 pieces) Accessories for Short Bars (P2DN) Cap Model Minimum order (bag) 1 (100 pcs./bag) P2DN-CP100 Mounting Tracks Applicable Socket Description Model Minimum order (quantity) 50 cm (l) × 7.3 mm (t): PFP-50N Mounting track Track-connecting Socket 1 m (l) × 7.3 mm (t): PFP-100N 1 m (l) × 16 mm (t): PFP-100N2 End plate *1 PFP-M Spacer PFP-S Back-connecting Socket Mounting plate *2 P2R-P --- 10 1 *1. When mounting DIN rail, please use End Plate (PFP-M). *2. Used to mount several P2R-05A and P2R-08A Connecting Sockets side by side. 2 G2R-@-S (S) Specifications Coil Ratings Rated current* Rated voltage 50 Hz AC 60 Hz Armature OFF 43.5 mA 37.4 mA 253 Ω 0.81 48 V 21.8 mA 18.8 mA 1,040 Ω 3.12 6.17 110 V 9.5 mA 8.2 mA 5,566 Ω 13.33 26.83 120 V 8.6 mA 7.5 mA 7,286 Ω 16.13 32.46 230 V 4.4 mA 3.8 mA 27,172 Ω 72.68 143.90 240 V 4.2 mA 3.7 mA 27,800 Ω 90.58 182.34 Rated current* Coil resistance Must release voltage Max. voltage % of rated voltage Power consumption (approx.) 1.55 Coil inductance (H) (ref. value) Armature OFF Must operate voltage Armature ON 24 V Rated voltage DC Coil resistance Coil inductance (H) (ref. value) 80% max. 30% max. Must operate voltage Must release voltage Armature ON 6V 87.0 mA 69 Ω 0.25 12 V 43.2 mA 278 Ω 0.98 2.35 24 V 21.6 mA 1,113 Ω 3.60 8.25 48 V 11.4 mA 4,220 Ω 15.2 29.82 110% Max. voltage % of rated voltage 0.9 VA at 60 Hz Power consumption (approx.) 0.48 70% max. 15% min. 110% 0.53 W Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C with tolerances of +15%/-20% for the AC rated current and ±10% for the DC coil resistance. 2. The AC coil resistance and inductance values are reference values only (at 60 Hz). 3. Operating characteristics were measured at a coil temperature of 23°C. 4. The maximum voltage is the maximum possible value of the voltage that can be applied to the relay coil. It is not the maximum voltage that can be applied continuously. Contact Ratings Number of poles 1 pole Load Resistive load (cosφ = 1) Inductive load (cosφ = 0.4; L/R = 7 ms) Resistive load (cosφ = 1) 2 poles Inductive load (cosφ = 0.4; L/R = 7 ms) Rated load 10 A at 250 VAC; 10 A at 30 VDC 7.5 A at 250 VAC; 5 A at 30 VDC 5 A at 250 VAC; 5 A at 30 VDC 2 A at 250 VAC; 3 A at 30 VDC Rated carry current 10 A 5A Max. switching voltage 440 VAC, 125 VDC 380 VAC, 125 VDC Max. switching current 10 A Max. switching power 2,500 VA, 300 W Failure rate (reference value) * 100 mA at 5 VDC 5A 1,875 VA, 150 W 1,250 VA, 150 W 500 VA, 90 W 10 mA at 5 VDC Note: P level: λ60 = 0.1 x 10-6/operation * This value was measured at a switching frequency of 120 operations per minute. 3 G2R-@-S (S) Characteristics Item 1 pole 2 poles Contact configration SPDT Contact structure Single Contact resistance 100 mΩ max. Operate (set) time 15 ms max. Release (reset) time AC: 10 ms max.; DC: 5 ms max. (w/built-in diode: 20 ms max.) Max. operating frequency Mechanical: Electrical: Insulation resistance 1,000 MΩ min. (at 500 VDC) Dielectric strength * 5,000 VAC, 50/60 Hz for 1 min between coil and 5,000 VAC, 50/60 Hz for 1 min between coil and contacts; contacts; 3,000 VAC, 50/60 Hz for 1 min between contacts of different polarity 1,000 VAC, 50/60 Hz for 1 min between contacts of 1,000 VAC, 50/60 Hz for 1 min between contacts of same polarity same polarity Vibration resistance Destruction: Malfunction: 10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude) 10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude) Shock resistance Destruction: Malfunction: 1,000 m/s2 200 m/s2 when energized; 100 m/s2 when not energized Mechanical: AC: 15 ms max.; DC: 10 ms max. (w/built-in diode: 20 ms max.) 18,000 operations/hr 1,800 operations/hr (under rated load) Electrical: AC coil: 10,000,000 operations min.; DC coil: 20,000,000 operations min. (at 18,000 operations/hr) 100,000 operations min. (at 1,800 operations/hr under rated load) Ambient temperature Operating: –40°C to 70°C (with no icing or condensation) Ambient humidity Operating: 5% to 85% Weight Approx. 20 g Endurance Note: Values in the above table are the initial values. * These values are relay only. Prease refer to the “Products Related to Common Sockets and DIN Tracks Data Sheet” for connecting sockets. Approved Standards IEC/VDE (Certificate No. 40015012 EN 61810-1) UL 508 (File No. E41643) Model Contact Coil ratings form Contact ratings Operations G2R-1-S (S) SPDT 10 A, 30 VDC (resistive) 100 × 103 10 A, 250 VAC (general use) G2R-2-S (S) DPDT 25 × 103 5 to 110 VDC TV-3 (NO contact only) 6 to 240 VAC 5 A, 30 VDC (resistive) 100 × 103 5 A, 250 VAC (general use) TV-3 (NO contact only) 25 × 103 CSA 22.2 No.0, No.14 (File No. LR31928) Model Contact Coil ratings form Contact form Operations G2R-1-S (S) SPDT 10 A, 30 VDC (resistive) 100 × 103 10 A, 250 VAC (general use) G2R-2-S (S) DPDT 25 × 103 5 to 110 VDC TV-3 (NO contact only) 6 to 240 VAC 5 A, 30 VDC (resistive) 100 × 103 5 A, 250 VAC (general use) TV-3 (NO contact only) Contact ratings Operations 1 pole 6, 12, 24, 48 VDC 24, 110, 120, 230, 240 VAC 5 A, 440 VAC (cosφ = 1.0) 10 A, 250 VAC (cosφ = 1.0) 10 A, 30 VDC (0 ms) 100 × 103 2 poles 6, 12, 24, 48 VDC 24, 110, 120, 230, 240 VAC 5 A, 250 VAC (cosφ =1.0) 5 A, 30 VDC (0 ms) 100 × 103 LR Number of poles Contact ratings Coil ratings Coil ratings Contact ratings Operations 1 pole 5 to 110 VDC 6 to 240 VDC 10 A, 250 VAC (general use) 7.5 A, 250 VAC (PF0.4) 10 A, 30 VDC (resistive) 5A, 30VDC (L/R=7ms) 100 × 103 2 poles 5 to 110 VDC 6 to 240 VDC 5 A, 250 VAC (general use) 2 A, 250 VAC (PF0.4) 5 A, 30 VDC (resistive) 3A, 30VDC (L/R=7ms) 100 × 103 25 × 103 4 G2R-@-S (S) Engineering Data Maximum Switching Power G2R-2-S (S) G2R-1-S (S) 100 Switching current (A) AC inductive load (cosφ = 0.4) AC resistive load 10 DC resistive load DC inductive load (L/R = 7 ms) 1 0.1 1 10 100 Switching current (A) 100 AC resistive load DC resistive load 1 0.1 1000 AC inductive load (cosφ = 0.4) 10 DC inductive load (L/R = 7 ms) 1 Switching voltage (V) 10 100 1000 Switching voltage (V) Endurance G2R-2-S (S) 10,000 5,000 1,000 250-VAC/30-VDC resistive load 500 100 250-VAC inductive load (cosφ = 0.4) 30-VDC inductive load (L/R = 7ms) 50 Switching current (A) Endurance (x103 operations) Endurance (x103 operations) G2R-1-S (S) 5,000 1,000 500 30-VDC inductive load (L/R = 7ms) 250-VAC/30-VDC resistive load 100 250-VAC 50 inductive load (cosφ = 0.4) Switching current (A) Maximum voltage (%) Ambient Temperature vs Maximum Coil Voltage DC coil AC coil Ambient temperature (°C) 5 G2R-@-S (S) Dimensions (Unit: mm) Note: All units are in millimeters unless otherwise indicated. SPDT Relays G2R-1-S (S), G2R-1-SN (S), G2R-1-SNI (S) G2R-1-SD (S), G2R-1-SND (S), G2R-1-SNDI (S) Terminal Arrangement/Internal Connections (Bottom View) G2R-1-SD (S) (DC) G2R-1-S (S) 29 max. 1 13 max. 1 2 20 35.5 max. 5 4 3 G2R-1-SN (S), G2R-1-SNI (S) (AC) 4.75 2 5 3 4 4 2 5 3 7.5 0.5 1 5 1 24V 3 4 G2R-1-SN (S), G2R-1-SNI (S) (DC) 1 DC 2 5 G2R-1-SND (S), G2R-1-SNDI (S) (DC) 5.2 5.2 17.5 1 2 5 3 4 DPDT Relays G2R-2-S (S), G2R-2-SN (S), G2R-2-SNI (S) G2R-2-SD (S), G2R-2-SND (S), G2R-2-SNDI (S) Terminal Arrangement/Internal Connections (Bottom View) G2R-2-S (S) 1 2 3 4 8 7 6 5 13 max. 2.5 35.5 max. 1 2 3 4 8 7 6 5 G2R-2-SN (S), G2R-2-SNI (S) (DC) 1 2 3 4 1 2 3 4 8 7 6 5 8 7 6 5 7.4 8.9 2.4 G2R-2-SN (S), G2R-2-SNI (S) (AC) 6.2 20 29 max. 0.5 G2R-2-SD (S) (DC) G2R-2-SND (S), G2R-2-SNDI (S) (DC) 5 5 19.4 1 2 3 4 8 7 6 5 6 G2R-@-S (S) Track/Surface Mounting Sockets P2RF-05-PU 57.5 Terminal Arrangement/ Internal Connection Diagram (Top View) 53.1 A2 30.8 28.1 (4.2) (1) Mounting Hole Dimensions A1 (5) 25.6 Two M3 screw holes or two 3.5-dia. holes 108 90 Release lever 35.3 12 (2) 14 (3) 27.35 11 (4) (4.2) 3.9 15.5 34.3 43 52.1 P2RF-08-PU Note: Pull out the hooks to mount the Socket with screws. Note: The numbers in parentheses are traditionally used terminal numbers. 25.6 57.5 Terminal Arrangement/ Internal Connection Diagram (Top View) 53.1 30.8 28.1 (4.2) A2 (1) Mounting Hole Dimensions A1 (8) 25.6 Two M3 screw holes or two 3.5-dia. holes 90 Release lever 35.3 108 12 27.35 (4.2) 3.9 15.5 25.6 34.3 Application Pitch PYDN-7.75-@@ (7.75 mm) 3.90 L 12 For Coil terminals 1.57 PYDN-15.5-080@ (15.5 mm) 3.90 115.85 2.25 7.75 mm 18.5 2.25 12 For Contact terminals (common) 15.5 mm (7) 14 24 (4) (5) 11 21 (3) (6) Note: The numbers in parentheses are traditionally used terminal numbers. 43 52.1 Accessories for P2RF-@-PU Short Bars 22 (2) No. of poles L (Length) 2 15.1 3 22.85 4 30.6 20 154.6 8 115.85 Colors Note: Pull out the hooks to mount the Socket with screws. Model * Maximum carry current PYDN-7.75-020@ PYDN-7.75-030@ Red (R) Blue (S) Yellow (Y) PYDN-7.75-040@ 20 A PYDN-7.75-200@ PYDN-15.5-080@ * Replace the box (@) in the model number with the code for the covering color. Note: 1. Use the Short Bars for crossover wiring within one Socket or between Sockets. 2. When using short bar to coil terminals of PYF-@@-PU, make sure to use PYDN-31.0080@ (31 mm). When using short bar to coil terminals of P2RF-@@-PU, make sure to use PYDN-15.5080@ (15.5 mm). 18.5 1.57 7 G2R-@-S (S) P2RFZ-05-E Terminal Arrangement/ Internal Connection Diagram (Top View) 2 48 max. 5-M3X8 Mounting Hole Dimensions 3.2-dia. hole 4 (42.3) 10.5 2 39.5 3 78.5 max. 39.5±0.1 (35.8) 3.5-dia. hole 35.5 M3 or 3.5-dia. hole 17.2 4 5 31 max. 16 max. 1 61 max. P2RFZ-08-E 8-M3X8 Terminal Arrangement/ Internal Connection Diagram (Top View) 2 48 max. 2 (42.3) 39.5 6 3 7 2 5 4 Mounting Hole Dimensions 3.2-dia. hole 10.5 39.5±0.1 78.5 max. (35.8) 3.5-dia. hole 35.5 M3 or 3.5-dia. hole 17.2 4 8 1 31 max. 16 max. 61 max. Accessories for P2RFZ-@-E Short Bars P2DN-6.8-100S (6.8 mm) Maximum carry current: 20A 15.7±0.1 6.8±0.1 2.9 9 15.4 max. 8.7 max. 152.7 max. 2.5 max. P2DN-15.7-100S (15.7 mm) Maximum carry current: 20A 2.9 15.7±0.1 1.6-dia. 9 15.4 max. 8.7 max. 152.7 max. 2.5 max. Note: Each Short Bar set comes with 20 Caps. Accessories for P2DN Cap P2DN-CP100 5.2 max. 4 max. 6 max. 8 G2R-@-S (S) P2RF-05-E 7±0.2 Five, M3.5´7 2 48 max. Terminal Arrangement (Top View) 4 (12) 39.5 3 35.5 85.5 max. Mounting Holes (for Surface Mounting) 3.2-dia. hole (11) 2 (14) 39.5±0.1 3.5-dia. hole M3 or 3.5-dia. hole 5 (A1) (A2) 4 1 11.5 61 max. 16.0 max. Note: Pin numbers in parentheses apply to DIN standard. P2RF-08-E 6 +0.2 −0.1 2 Terminal Arrangement (Top View) 2 1.5 Eight, M3´8 48.0 max. Mounting Holes (for Surface Mounting) 3 39.5 (21) (22) (24) 6 3 7 5 2 4 (11) (12) (14) 3.2-dia. hole 35.5 39.5±0.1 85.5 max. 3.5-dia. hole 8 (A1) (A2) 4 61.0 max. 1 M3 or 3.5-dia. hole 11.5 16.0 max. P2RF-05 2 7 Terminal Arrangement (Top View) Five, M3.5 x 8 4-dia. holes Mounting Holes (for Surface Mounting) 4.2-dia. hole 35.5 71.5 max. 30±0.05 4 19.5 30 max. 19.5 max. M3 or 3.2-dia. hole 54 max. P2RF-08 2 7 Eight, M3.5 x 8 4-dia. holes Terminal Arrangement (Top View) Mounting Holes (for Surface Mounting) 4.2-dia. hole 35.5 71.5 max. 30±0.05 4 19.5 max. 19.5 30 max. 54 max. M3 or 3.2-dia. hole 9 G2R-@-S (S) Mounting Height of Relay with Track/Surface Mounting Sockets P2RF-05-PU P2RF-08-PU G2R-@-S (S) Relay G2R-@-S (S) Relay P2RF-05ーPU Socket P2RF-08ーPU Socket 63.6 63.6 28.1 28.1 (3.9) (3.9) P2RFZ-E G2R-@-S (S) Relay P2RFZ-@-E Socket 67.0 70.5 P2RF-@ P2RF-@-E G2R-@-S (S) Relay G2R-@-S (S) Relay P2RF-@-E Socket P2RF-@ Socket 66.5 62.0 67.0 70.5 10 G2R-@-S (S) Back-connecting Sockets P2R-05P (1-pole) 4 1 Terminal Arrangement (Bottom View) 14.5 max. 7 Mounting Holes Tolerance: ±0.1 4 6 4.5 6 35.5 max. 15 Five, 1.6-dia. holes 4.5 1.2 4 15 3.5 4 1.5 (5) 4 7 7 36.5 max. P2R-08P (2-pole) 4 0.3 Terminal Arrangement (Bottom View) 14.5 max. 7 Mounting Holes 7.5 Eight, 1.3-dia. holes 5 5 5 35.5 max. 20 1 5 20 2.8 1.5 (4.3) 7.5 Terminal plate thickness: 0.3 4.5 P2R-05A (1-pole) 36.5 max. 7.5 1.2 0.3 14.5 max. Terminal Arrangement (Bottom View) 6.7 3.8 35.5 max. 5 16.7 Panel Cutout Five, 3 x 1.8-dia. holes 13.6±0.1 6 36.5 max. Terminal plate thickness: 0.3 30.5±0.2 6.5 7.5 P2R-08A (2-pole) 0.3 14.5 max. 1.2 5 5 35.5 max. 20 2.6 Recommended thickness of the panel is 1.6 to 2.0 mm 2.8 1.5 Eight, 3 x 1.2-dia. holes 7.5 Terminal plate thickness: 0.3 36.5 max. 11 G2R-@-S (S) P2R-057P (1-pole) 0.7 14 max. 8.7 1 Mounting Holes Terminal Arrangement (Bottom View) 16.4 10.4 3.5 4±0.1 1 6 4.5 15 37 max.29.6 1 8.7 Five, 1.6-dia. holes 6±0.1 4 8.75 4.5±0.1 15±0.1 4±0.1 5 7.4 7±0.1 41 max. P2R-087P (2-pole) 14 max. 7.5 1 Mounting Holes Terminal Arrangement (Bottom View) 16.4 10.4 3.5 0.3 7.5 5 5 37 max. 29.1 20 1 5 5 8.1 8.9 Eight, 1.3-dia. holes 20 7.4 (8.1) 41 max. Mounting Height of Relay with Back-connecting Sockets P2R-@P P2R-@A P2R-@7P G2R-@-S (S) Relay G2R-@-S (S) Relay 44.5 G2R-@-S (S) Relay 47.5 38.0 P2R-@P Socket P2R-@A Socket P2R-@7P Socket Mounting Tracks PFP-100N, PFP-50N PFP-100N2 16 7.3±0.15 4.5 4.5 35±0.3 15 25 25 10 1,000 (500) 25 25 10 15 (5) 35±0.3 27 27±0.15 1 15 25 25 15 25 25 10 10 24 29.2 1 1.5 1,000 It is recommended to use a panel 1.6 to 2.0 mm thick. 12 G2R-@-S (S) End Plate Spacer 10 6.2 PFP-M PFP-S 16 12 5 1.8 1 50 1.8 11.5 10 M4 x 8 pan head screw 35.5 35.3 34.8 44.3 1.3 4.8 16.5 Mounting Plate P2R-P 90 R2.25 10-Ellipse hole 4.5 13.6 3.4 49 42±0.1 30.5 18±0.15 18±0.15 18±0.15 18±0.15 Square hole 9±0.1 72±0.2 9±0.1 t=1.6 mm 13 G2R-@-S (S) Safety Precautions Be sure to read the Common Precautions for All Relay in the website at the following URL: http://www.ia.omron.com/. Refer to Products Related to Common Sockets and DIN Tracks for precautions on the applicable Sockets. Refer to PYF-@@-PU/P2RF-@@-PU for precautions on Push-In Plus Terminal Block Sockets. Warning Indications CAUTION Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury or in property damage. • When cutting with a tool, insert the tool from the plastic part and cut along the slot in the plastic part between terminals. If you cut a part other than the slot in the plastic part between terminals, it may not be possible to attach the insulating cap. Supplementary comments on what to do Precautions for or avoid doing to prevent failure to operate, malfunction, or undesirable Correct Use effects on product performance. Cation • Do not use the test button for any purpose other than testing. Be sure not to touch the test button accidentally as this will turn the contacts ON. Before using the test button, confirm that circuits, the load, and any other connected item will operate safely. • Check that the test button is released before turning ON relay circuits. • If the test button is pulled out too forcefully, it may bypass the momentary testing position and go straight into the locked position. • Use an insulated tool when you operate the test button. • When using a cut short-circuit bar (P2DN), always use the provided cap to protect the charger part. Precautions for Correct Use About the Built-in Diodes The diodes that are built into the Relays are designed to absorb reverse voltage from the Relay’s coil. If a large surge in voltage is applied to the diode from an external source, the element will be destroyed. If there is the possibility of large voltage surges that could be applied to the elements from an external source, take any necessary surge absorption measures. • The proper orientation for installing the short-circuit bar is with the molded part facing inward. Latching Levers • Turn OFF the power supply when operating the latching lever. After you use the latching lever always return it to its original state. • Do not use the latching lever as a switch. • The latching lever can be used for 100 operations minimum. Relay Replacement To replace the Relay, turn OFF the power supply to the load and Relay coil sides to prevent unintended operation and possible electrical shock. Coil tape color Pink tape is used for the AC coil type and blue tape is used for the DC coil type, making it easy to distinguish AC and DC. Using a short-circuit bar • Use the short-circuit bar that is suitable for the socket you are using and the location of use. • Note that the P2DN short-circuit bar for the P2RFZ-E Socket has both a short-circuit bar for shorting coil terminals and a short-circuit bar for shorting contact COM terminals. • The short-circuit bar can be cut to match any number of poles. Cut with a tool as appropriate for the number of relays and sockets. When using a cut short-circuit bar, take care to avoid injuring yourself on the cut surface. • Use the short-circuit bar to short-circuit two or more coil terminals, or two or more contact COM terminals. • Do not use a deformed short-circuit bar. Risk of failure, malfunctioning, or deterioration of characteristics. • In socket terminals, insert the short-circuit bar in the correct orientation all the way into all terminals, and then secure with screws. • Install the short -circuit bar before wiring. Equivalent Labels from Other Companies and Recommended Label Printers Use the following label printer. The following table gives the manufacturer’s model number as of March 2017. Manufacturer Label Label printer Omron Phoenix Contact XW5Z-P4.0LB1 UCT-TM6 XW5Z-P2.5LB2 UCT-TMF5 --- * BLUEMARK CLED, THERMOMA RK CARD SET PLUS, THERMOMA RK CARD Weidmuller MF 10/6 --- Cembre MG-CPM-04 41391 --- PrintJet ADVCANCED, Plotter MCP Markingenius Plus, MG3 Plotter MCP Basic * When using a printing tool, use a Phoenix Contact label printer. Note: Ask the label manufacturer or printer manufacturer for details. 14 OMRON AUTOMATION AMERICAS HEADQUARTERS • Chicago, IL USA • 847.843.7900 • 800.556.6766 • automation.omron.com OMRON CANADA, INC. • HEAD OFFICE Toronto, ON, Canada • 416.286.6465 • 866.986.6766 • automation.omron.com OMRON ELETRÔNICA DO BRASIL LTDA • HEAD OFFICE São Paulo, SP, Brasil • 55 11 5171-8920 • automation.omron.com OMRON ELECTRONICS DE MEXICO • HEAD OFFICE Ciudad de México • 52.55.5901.4300 • 01.800.386.6766 • mela@omron.com OMRON ARGENTINA • SALES OFFICE Buenos Aires, Argentina • +54.11.4521.8630 • +54.11.4523.8483 mela@omron.com OMRON ELECTRONICS DE MEXICO • SALES OFFICE San Pedro Garza García, N.L. • 81.12.53.7392 • 01.800.386.6766 • mela@omron. com OTHER OMRON LATIN AMERICA SALES +54.11.4521.8630 • +54.11.4523.8483 • mela@omron.com OMRON ELECTRONICS DE MEXICO • SALES OFFICE Eugenio Garza Sada,León, Gto • 01.800.386.6766 • mela@omron.com Controllers & I/O • Machine Automation Controllers (MAC) • Motion Controllers • Programmable Logic Controllers (PLC) • Temperature Controllers • Remote I/O Authorized Distributor: Robotics • Industrial Robots • Mobile Robots Operator Interfaces • Human Machine Interface (HMI) Motion & Drives • Machine Automation Controllers (MAC) • Motion Controllers • Servo Systems • Frequency Inverters Vision, Measurement & Identification • Vision Sensors & Systems • Measurement Sensors • Auto Identification Systems Sensing • Photoelectric Sensors • Fiber-Optic Sensors • Proximity Sensors • Rotary Encoders • Ultrasonic Sensors Safety • Safety Light Curtains • Safety Laser Scanners • Programmable Safety Systems • Safety Mats and Edges • Safety Door Switches • Emergency Stop Devices • Safety Switches & Operator Controls • Safety Monitoring/Force-guided Relays Control Components • Power Supplies • Timers • Counters • Programmable Relays • Digital Panel Meters • Monitoring Products Switches & Relays • Limit Switches • Pushbutton Switches • Electromechanical Relays • Solid State Relays Software • Programming & Configuration • Runtime J140-E3-02 Note: Specifications are subject to change. © 2020 Omron. All Rights Reserved. Printed on recycled paper. Printed in U.S.A.
G2R-1-SNI DC24(S) 价格&库存

很抱歉,暂时无法提供与“G2R-1-SNI DC24(S)”相匹配的价格&库存,您可以联系我们找货

免费人工找货